SYMPTOM
P0505 - IDLE AIR CONTROL MOTOR CIRCUITS
WHEN MONITORED
At key ON and battery voltage greater than 11.5 volts.
SET CONDITION
The PCM senses a short to ground or battery voltage on any of the four Idle Air Control (IAC) driver circuits for 2.75 seconds while the IAC motor is active.
POSSIBLE CAUSES
- IAC motor circuit wiring harness observable defective
- IAC motor circuit wiring harness intermittent defective
- IAC # 4 driver circuit shorted to ground
- IAC # 1 driver circuit shorted TO # 2, # 3, or # 4
- IAC # 2 driver circuit shorted to # 3 or # 4
- IAC # 3 driver circuit shorted to # 4
- IAC motor defective
- IAC # 1 driver circuit shorted to ground
- IAC # 2 driver circuit shorted to ground
- IAC # 3 driver circuit shorted to ground
- PCM defective (IAC # 1 driver)
- PCM defective (IAC # 2 driver)
- PCM defective (IAC # 3 driver)
- PCM defective (IAC # 4 driver)