Decklid Security (Knockout) Switch Missing
Test 348 - 353:
SYMPTOM
DECKLID SECURITY (KNOCKOUT) SWITCH MISSING
WHEN MONITORED
During configuration of the Remote Keyless Entry Module (with ignition ON).
SET CONDITION
If the decklid security switch input to the RKE module is not grounded while being configured for VTSS this code will set.
POSSIBLE CAUSES
- DRB VTSS security switch check ok
- Decklid security switch defective-open
- RKE module defective-decklid switch open
- Decklid security switch sense wire open