Fuel Level Sensor Shorted
Test 138 - 141:
SYMPTOM
FUEL LEVEL SENSOR SHORT
WHEN MONITORED
When the ignition is ON.
SET CONDITION
The Instrument Cluster monitors the fuel level sensor signal circuit for a resistance value between approximately 25 ohms to 1100 ohms. If the Cluster senses a resistance less than 25 ohms, this code will set.
POSSIBLE CAUSES
- Defective instrument - shorted fuel level
- Fuel level sensor shorted
- Fuel level sensor signal wire short to ground