Bus +/- Signal Open From SKIM
Tests 57 - 60:
Test 61:
SYMPTOM
BUS +/- SIGNAL OPEN FROM SKIM
POSSIBLE CAUSES
- PCI Bus open circuit to SKIM
- SKIM fused B(+) open
- SKIM fused ignition switch output circuit open
- SKIM ground circuit open
- SKIM response failure