P0732
Test 246 Through 249:
Test 250:
Symptom:
P0732-GEAR RATIO ERROR IN 2ND
When Monitored and Set Condition:
P0732-GEAR RATIO ERROR IN 2ND
When Monitored:
The transmission gear/speed ratio is monitored continuously while the transmission is in gear.
Set Condition:
Code P0732 is set if the ratio of the input RPM to the output RPM does not match the given gear ratio.
POSSIBLE CAUSES
CHECKING SYMPTOMS AND POSSIBLE CAUSES
LOW BATTERY VOLTAGE CAUSING SYMPTOM
INTERMITTENT CODE P0732
Test 108 Through 112:
Test 113 Through 117:
Symptom:
ADDITIONAL GEAR RATIO ERROR IN 2ND (P0732)
POSSIBLE CAUSES
CUST COMPLAINT INTERMITTENT 2ND GEAR SLIPPAGE
UD AND 2-4 CVI'S OUT OF SPEC
UD AND 2-4 PRESSURE < 105 PSI
UD PRESSURE < 5 PSI IN 4TH GEAR
TRANSAXLE DEFECT (2-4 SEALS)
2-4 ACCUM SEALS WELDED TOGETHER
UD ACCUMULATOR SEALS WELDED TOGETHER
TRANSAXLE DEFECT(UD SEALS)
TRANSAXLE SEALS ARE DEFECTIVE
UD PRESSURE > 5 PSI IN 4TH GEAR
TRANS HAS PLASTIC 2-4 ACCUM/SEAL