Driver Squib Circuit Shorted (Active)
SYMPTOMDRIVER SQUIB CIRCUIT SHORTED (ACTIVE)
WHEN MONITORED
Continuously with ignition on.
SET CONDITION
The ACM has detected low resistance in the Driver Squib Circuits.
POSSIBLE CAUSES
- Driver airbag connector disconnected
- Driver airbag line 1 shored to driver airbag line 2
- Clockspring shorted
- Driver airbag module shorted
- ACM defective driver airbag circuit shorted