Low Pressure Sensor / Switch: Service and Repair
WARNING: THE REFRIGERATION SYSTEM MUST BE COMPLETELY RECOVERED BEFORE PROCEEDING WITH THIS OPERATION. REFER TO REFRIGERANT RECOVERY.REMOVAL
1. Disconnect the boot like wire connector at the cut off switch.
Low Pressure Cut-off Switch And Expansion Valve - Typical:
2. Using a sender unit removal socket, remove the switch from the expansion valve.
INSTALLATION
NOTE: Verify the O-ring condition on the replacement switch.
- For installation, reverse the above procedures. Evacuate and charge the system.