Loss of Ignition Run/Start (Active)
SYMPTOM:LOSS OF IGNITION RUN/START (ACTIVE)
WHEN MONITORED:
Continuously with the ignition ON.
SET CONDITION:
With ignition ON, the ignition run/start circuit voltage is other than expected.
POSSIBLE CAUSES
- ACM Defective, fused ignition run/start open
- ACM Defective, fused ignition run/start shorted
- Fuse #9 Defective
- Fused ignition SW output run/start shorted to GND
- Fused ignition Switch output run/start open
- Ignition Switch output run/start open