Ignition Power Transistor Inspection
NOTE: An analog-type circuit tester should be used.Ignition Power Transistor:
Ignition Power Transistor Continuity Table:
No. 1 - No. 4 Coil Side
1. Connect the negative (-) terminal of the 1.5 V power supply to terminal (4) of the ignition power transistor; then check whether there is continuity between terminal (13) and terminal (4) when terminal (3) and the positive (+) terminal are connected and disconnected.
NOTE: Connect the (-) probe of the circuit tester to terminal (13).
2. Replace the ignition power transistor if there is a malfunction.
Ignition Power Transistor:
Ignition Power Transistor Continuity Table:
No. 2 - No. 5 Coil Side
1. Connect the negative (-) terminal of the 1.5 V power supply to terminal (4) of the ignition power transistor; then check whether there is continuity between terminal (12) and terminal (4) when terminal (2) and the positive (+) terminal are connected and disconnected.
NOTE: Connect the (-) probe of the circuit tester to terminal (12).
2. Replace the ignition power transistor if there is a malfunction.
Ignition Power Transistor:
Ignition Power Transistor Continuity Table:
No. 3 - No. 6 Coil Side
1. Connect the negative (-) terminal of the 1.5 V power supply to terminal (4) of the ignition power transistor; then check whether there is continuity between terminal (11) and terminal (4) when terminal (1) and the positive (+) terminal are connected and disconnected.
NOTE: Connect the (-) probe of the circuit tester to terminal (11).
2. Replace the ignition power transistor if there is a malfunction.