Positive Crankcase Ventilation Valve: Testing and Inspection
1. Remove the PCV valve.
2. Insert a thin rod from the threaded end of the PCV valve and verify that the valve plunger moves freely.
3. If the valve does not operate freely or is clogged replace it.