Transmission Range Sensor Circuit Malfunction (PRNDL Input)
FAULT IDP0705
TITLE
Transmission Range Sensor Circuit Malfunction (PRNDL Input)
BACKGROUND
- When a malfunction of the park/neutral position switch is detected, the transaxle control module outputs a malfunction signal to the engine control module.
RANGE OF CHECK/SET CONDITIONS
- The park/neutral position switch failure signal is input to the engine control module.
PROBABLE CAUSES
- Park/neutral position switch failed.
- Open or shorted park/neutral position switch circuit, or loose connector.
- Engine control module failed.