Neutral Safety Switch: Description and Operation
CIRCUIT OPERATIONWhen CLOSED, the [1][2]park/neutral position switch provides a ground path on circuit T41 for the coil side of the engine starter motor relay The case grounded switch provides ground for circuit T41.
Circuit A41 from the ignition switch provides battery voltage to the coil side of the relay.