High Pressure Sensor / Switch: Service and Repair
WARNING: The refrigerant must be removed from the system before removing the high pressure cut out switch.REMOVAL
High Pressure Relief Valve:
1. Disconnect wiring connector at the switch.
2. Remove internal snap ring.
3. Pull switch out of manifold.
INSTALLATION