Initiator (Squib) Open
When Monitored: With the ignition on.Set Condition: Any variance from normal current flow as sensed by the ASDM.
Possible Causes:
- Air bag (squib) module short
- Clock spring open
- Loose or poor connections at connector terminals
- Air bag line 1 or 2 open