Bench Testing
Starter Solenoid1. Disconnect field coil wire from field coil terminal.
2. Check for continuity between solenoid terminal and field coil terminal. There should be continuity.
3. Check for continuity between solenoid terminal and solenoid housing. There should be continuity.
4. If there is no continuity in either test, replace solenoid assembly.