Self Centering Combination Valve

Combination valves containing brake warning or pressure differential type valves are self-centering. They will reset after hydraulic system pressure is equalized, and after the following procedure: Upon completion of bleeding the hydraulic system, depress the brake pedal with moderate force. The brake warning lamp will turn off when the switch is becomes centered.