Installation
INSTALLATION
1. Be sure both end of manifold and limiting valve mounting area are clean.
2. Lubricate O-ring on limiting valve with fresh diesel oil. Also lubricate limiting valve threads with fresh diesel oil.
3. Install the limiting valve (1). Tighten to 100 Nm (74 ft. lbs.).
4. Using a new gasket (7), install the intake manifold (2). Tighten bolts (1) to 24 Nm (18 ft. lbs.).
5. Install the EGR crossover tube Exhaust Gas Recirculation (EGR) Tube - Installation
6. Using a diagnostic scan tool, reset vale life by using the "Reset Two-Stage Dump Valve Accumulator" function in the PCM portion of the diagnostic tool.
7. Start engine and check for leaks.