3-4 Solenoid Circuit Shorted to Ground
Symptom List:3-4 SOLENOID CIRCUIT
3-4 SOLENOID CIRCUIT SHORT TO GROUND
Test 1-4:
Test 5-7:
Test Note: All symptoms listed above are diagnosed using the same tests. The title for the tests will be 3 4 SOLENOID CIRCUIT.
3-4 SOLENOID CIRCUIT
When Monitored:
Always monitored with system active at each ignition cycle.
Set Condition:
If the TCM detects a short to ground or battery on the solenoid control circuit, shorted solenoid, open solenoid, or an open or shorted solenoid control circuit driver in the TCM.
3-4 SOLENOID CIRCUIT SHORT TO GROUND
When Monitored:
Always monitored with system active at each ignition cycle.
Set Condition:
If the TCM detects a short to ground or battery on the solenoid control circuit, shorted solenoid, open solenoid, or an open or shorted solenoid control circuit driver in the TCM.
POSSIBLE CAUSES
- INTERMITTENT WIRING AND CONNECTORS
- 3-4 SOLENOID CONTROL CIRCUIT OPEN
- 3-4 SOLENOID CONTROL CIRCUIT SHORT TO GROUND
- 3-4 SOLENOID CONTROL CIRCUIT SHORT TO OTHER CIRCUITS
- 3-4 SOLENOID
- TCM - 3-4 SOLENOID CIRCUIT