Air Inlet Housing
HOUSING-AIR INLET
NOTE: The air inlet housing must be removed from HVAC housing and disassembled for service of the recirculation-air door.
NOTE: LHD model shown. RHD model similar.
1. Remove the air inlet housing (1) from the HVAC housing and place it on a workbench HVAC Housing - Removal.
2. Remove the two screws (2) that secure the recirculation door actuator (3) to the air inlet housing and remove the actuator.
3. Remove the recirculation-air door (4) from the air inlet housing.