Top - Retractable Hard Top - RHT
REMOVAL
NOTE: The hydraulic system uses ARAL VITAMOL ZH-M fluid. When replacing components or topping off system due to leak, make sure to use only approved fluid. When adding fluid Convertible Top - Standard Procedure.
1. Open top to the vertical position.
2. Support the top so as it does not fall when the cylinder is removed.
3. Remove fasteners to hydraulic cylinder.
4. At the hydraulic cylinder, slide the retaining clamp off and pull out line.
5. Separate the cylinder from vehicle.