Occupant Restraint Controller
OCCUPANT RESTRAINT CONTROLLER
1. Connect the two ORC connectors (4 and 5) and ensure that the connectors are engaged.
2. Position ORC (3) (arrow pointing forward) on the console floor bracket and mounting studs (1).
3. Install the three ORC retaining nuts (2) and tighten to 9 Nm (79.5 in. lbs.).
4. Install the center console Center Console - Installation.
WARNING: Do not connect the battery negative cable Refer to appropriate testing. Serious or fatal injury may result if the system test is not performed first.