IPM-64
IPM-64-INTERNAL IPM FAILURE
For a complete wiring diagram Consult Diagrams/Electrical
- When Monitored:
Continuously.
- Set Condition:
Time to mature is 125ms.
Diagnostic Test
1. INTERNAL IPM FAILURE
Connect the scan tool to the Data Link Connector.
Turn the ignition on.
With the scan tool, erase DTC's.
Turn the ignition off then turn the ignition on and wait approximately 1 minute.
With the scan tool, read DTC's.
Did this DTC reset?
Yes
- Replace the IPM.
- Perform the BODY VERIFICATION TEST - VER 1. Body Verification Test.
No
- Test Complete.