ABM Internal
Symptom:ABM INTERNAL
When Monitored:
Ignition On - Continuously
Set Condition:
When one of two internal CPUs, fails the programmed self test within the ABM.
Test 1-2:
Test 3-7:
POSSIBLE CAUSES
- INTERMITTENT DTC
- DAMAGED ABM/ABM HARNESS CONNECTOR
- FUSED RUN RELAY OUTPUT CIRCUIT OPEN
- ABS VALVE FUSED B(+) CIRCUIT OPEN
- ABS PUMP FUSED B(+) CIRCUIT OPEN
- ABM - GROUND CIRCUIT OPEN
- ABM - INTERNAL FAULT