Air Diverter Solenoid: Service and Repair
SWITCHOVER SOLENOIDREMOVAL
1. Disconnect the negative battery cable.
2. Remove the air cleaner housing.
3. Disconnect the air pump switchover solenoid harness connector (2).
4. Disconnect the vacuum lines (1).
5. Pull the air pump switchover solenoid locking tab (1) away from air pump switchover solenoid (2).
6. Remove the air pump switchover solenoid (2) from air pump switchover solenoid retaining bracket (3).
INSTALLATION
1. Position the air pump switchover solenoid (2) above air pump switchover solenoid mounting bracket (3) and lower until air pump switchover solenoid locking tab (1) snaps into place.
2. Connect the vacuum lines (1).
3. Connect the air pump switchover solenoid harness connector (2).
4. Install the air cleaner housing.
5. Connect the negative battery cable.