Early Production (SBEC)
Test 1 - 4:
Test 5 - 8:
Test 9 - 12:
Test 13 - 14:
SYMPTOM
P0172-1/1 FUEL SYSTEM RICH
WHEN MONITORED
With the engine running in closed loop mode, the ambient/battery temperature above 20 deg. F and altitude below 8000 ft.
SET CONDITION
If the PCM multiplies short term compensation by long term adaptive and the result is below a certain value for two trips, a freeze frame is stored, the MIL illuminates and a trouble code is stored.
POSSIBLE CAUSES
- Good trip equal to zero
- O2 sensor heater operation
- O2 sensor
- Evap purge solenoid operation
- O2 sensor signal circuit shorted to voltage
- O2 sensor signal circuit open
- TP sensor voltage greater than 0.92 volts with throttle closed
- TP sensor sweep
- MAP sensor operation
- ECT sensor operation
- Engine mechanical problem
- Fuel filter/pressure regulator (high)
- PCM