Valve Power Feed Failure
Test 1-2:
Test 3-7:
Test 8-10:
Symptom:
VALVE POWER FEED FAILURE
When Monitored:
Ignition on. The CAB monitors its internal microprocessors for correct operation.
Set Condition:
If the CAB detects an internal fault, the DTC is set.
POSSIBLE CAUSES
- Intermittent DTC
- ABS Valve Fuse
- ABS Valve Fused B(+) Supply Circuit Open
- ABS Valve Fused B(+) Circuit Open
- ABS Valve Fused B(+) Circuit Intermittent Short to Ground
- ABS Valve Fused B(+) Circuit Short to Ground
- Damaged Cab/Cab Harness Connector
- Cab - Ground Circuit Open
- Cab - Internal Fault