Inspection Procedure 2
When the Air Outlet Changeover Control Knob is Moved to Defroster or Defroster/Foot Position, the A/C or the Inside/Outside Air Changeover Damper Motor does not Operate.DIAGNOSIS
STEP 1. Check the defroster switch continuity.
Q: Is the defroster switch In good condition?
YES: Go to Step 2.
NO: Replace. Then go to Step 2.
STEP 2. Check each A/C part.
Refer to Inspection Procedure 1.
Q: Is the A/C operating properly?
YES: This diagnosis is complete. (If no malfunctions are not found in all steps, an intermittent malfunction is suspected. Refer to Introduction, How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction)
NO: Go to Step 1.