FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

P1195

Test 1:




Test 2 - 5:






SYMPTOM
P1195-1/1 O2 SENSOR SLOW DURING CATALYST MONITOR

WHEN MONITORED
With the engine running, coolant greater than 70° C (158° F), open throttle, steady to slightly increasing vehicle speed greater than 18 mphbut less than 55 mph, with a light load on the engine, for a period no less than 5 minutes.

SET CONDITION
The oxygen sensor signal voltage is switching from below 0.39 volt to above 0.6 volts and back fewer times than required.

POSSIBLE CAUSES
- Good trip equal to zero
- Exhaust leak
- O2 sensor signal circuit voltage drop
- O2 sensor ground circuit voltage drop
- O2 Sensor