P1195

Test 1:




Tests 2 - 5:




Test 6:




SYMPTOM
P1195-1/1 O(2) SENSOR SLOW DURING CATALYST MONITOR

WHEN MONITORED
With the engine running, coolant greater than 70 °C (158 °F), open throttle, steady to slightly increasing vehicle speed greater than 18 mph but less than 55 mph, with a light load on the engine, for a period no less than 5 minutes.

SET CONDITION
The oxygen sensor signal voltage is switching from below 0.39 volt to above 0.6 volts and back fewer times than required.

POSSIBLE CAUSES
- Intermittent Condition
- Exhaust Leak
- O(2) Sensor Signal Circuit Voltage Drop
- O(2) Sensor Ground Circuit Voltage Drop
- O(2) Sensor