P0133
Tests 1 - 3:
Tests 4 - 6:
SYMPTOM
P0133-1/1 O(2) SENSOR SLOW RESPONSE
WHEN MONITORED
Start engine. Allow engine to idle. For 1st part of test, if limits are exceeded, test passes. If not 2nd part of test runs. Ambient Temp great than 6.6 °C (44 °F), Baro greater than 22.13 Hg, Battery voltage 10.5 volts, MAP greater than 11.9 and less than 18.15" Hg, RPM greater than 1216 and less than 1984 and VSS greater 19 and less than 46 MPH.
SET CONDITION
The oxygen sensor signal voltage is switching from below 0.33 volts to above 0.61 volts and back fewer times than required in 60 seconds. Two trip fault.
POSSIBLE CAUSES
- Intermittent Condition
- Exhaust Leak
- O(2) Sensor Signal Circuit Voltage Drop
- O(2) Sensor Ground Circuit Voltage Drop
- O(2) Sensor