6: Condenser Fan Does Not Operate
INSPECTION PROCEDURE 6: Condenser Fan does not OperateRefer to - Radiator Fan and Condenser Fan Drive Circuit
CIRCUIT OPERATION
^ The fan control module is powered from fusible link number 2.
^ The ECM
TECHNICAL DESCRIPTION
The cause could be a malfunction of the condenser fan motor or of the fan control module.
TROUBLESHOOTING HINTS
^ Malfunction of condenser fan motor
^ Malfunction of fan control module
DIAGNOSIS
Step 1.Check the condenser fan motor.
Refer to - Condenser and Condenser Fan Motor.
Q:Is the condenser fan in good condition?
Yes: Go to Step 2
No: Replace the condenser fan motor. Then go to Step 3.
Step 2.Check the fan control module.
Q:Is the fan control module in good condition?
Yes: Go to Step 3.
No: Replace the fan control module, then go to Step 3.
Step 3.Check the symptoms.
Q:Does the condenser fan operate correctly?
Yes: This diagnosis is complete.
No: Return to Step 1.