Manifold Pressure/Vacuum Sensor: Service and Repair
REMOVAL1. Remove the negative battery cable.
Fig.16 MAP Sensor - 2.7L:
2. Disconnect the electrical connector from the MAP sensor.
3. Remove bolt from sensor.
4. Remove sensor.
INSTALLATION
Fig.17 MAP Sensor O-Ring:
1. The sensor mounts onto intake manifold plenum. Tighten screws to 4.5 Nm (40 in. lbs.) torque.
2. Attach electrical connector to sensor.
3. Install the negative battery cable.