Programming and Relearning
STANDARD PROCEDURE - TOGGLING CUSTOMER PREFERENCESDECK LID RELEASE TOGGLE
Deck lid release toggle is programmed to immediate release or press and hold release by continually pressing the unlock button for a minimum of 4 seconds to a maximum of 10 seconds. Within the 4-10 second range, the deck lid release button is depressed. Both buttons are then released.
HORN CHIRP TOGGLE
Once the transmitters have been programmed, the horn chirp can be enabled/disabled by sending the horn chirp toggle operation code to the Body Control Module (BCM). This can be done using a DRBIII(R) scan tool or by the customer. The horn chirp will enter the opposite state of its current programmed state by receiving this operation code. The BCM is responsible for keeping track of the horn chirp status.