Memory Position #2 Stuck
Test 1 - 3:
SYMPTOM
MEMORY POSITION # 2 STUCK
WHEN MONITORED
Ignition on.
SET CONDITION
If the switch is active for 30 seconds the MHSMM will ignore the input until the state has changed. Once the stuck position is removed the seat will return to normal operation. The code will remain in memory for 20 ignition cycles.
POSSIBLE CAUSES
- Memory position 2 switch sense circuit shorted to ground
- Memory set switch
- Memory heated seat mirror module