P1739
P1739-POWER UP AT SPEED
When Monitored and Set Condition:
P1739-POWER UP AT SPEED
When Monitored: When TCM (Transmission Control Module) initially powers-up.
Set Condition: If the TCM powers up and senses a valid forward gear PRNDL DTC and the Output RPM is above 800 RPM (approximately 32 Km/h or 20 MPH) then the DTC will set.
POSSIBLE CAUSES:
POWER UP AT SPEED