P1717
P1717-NO COMMUNICATION WITH THE MIC
When Monitored and Set Condition:
P1717-NO COMMUNICATION WITH THE MIC
When Monitored: Continuously with engine running.
Set Condition: The code sets in approximately 25 seconds if no BUS messages are received form the MIC.
POSSIBLE CAUSES:
OTHER BUS PROBLEMS PRESENT
INTERMITTENT WIRING AND CONNECTORS
MIC - NO COMMUNICATIONS
TCM - BUS COMMUNICATIONS