ORC Loss of Ignition Run Only (Stored)
Test 1:
SYMPTOM
ORC, LOSS OF IGNITION RUN ONLY - STORED
TEST NOTE
This symptom is diagnosed using the test ORC, CALIBRATION MISMATCH - STORED.
WHEN MONITORED
With the ignition in the run position the ORC monitors the Fused Ignition Switch Output Run circuit for proper system voltage.
SET CONDITION
If the voltage on the Fused Ignition Switch Output Run circuit drops below 4.5 volts, the code will set.
POSSIBLE CAUSES
- Checking for active ORC DTC's
- Stored code present