Left SIACM Curtain Squib Shorted to Ground (Stored)
Test 1:
SYMPTOM
LEFT SIACM, CURTAIN SQUIB SHORT TO GROUND - STORED
TEST NOTE
This symptom is diagnosed using the test LEFT SIACM, CURTAIN SQUIB CIRCUIT OPEN - STORED.
WHEN MONITORED
When the ignition is ON, the Left SIACM monitors the resistance of the left Curtain Squib circuits for low resistance.
SET CONDITION
The Left SIACM has detected a short to ground in the left Curtain Squib circuits.
POSSIBLE CAUSES
- Checking for active left SIACM DTCs
- Stored code present