Low Pressure Sensor / Switch: Service and Repair
REMOVAL
WARNING: THE REFRIGERATION SYSTEM MUST BE COMPLETELY RECOVERED BEFORE PROCEEDING WITH THIS OPERATION. REFER TO REFRIGERANT RECOVERY.
1. Recover A/C refrigerant.
2. Disconnect the wire connector at the cut off switch.
Fig.7 Expansion Valve And Low Pressure Cut-off Switch:
3. Using a sender unit removal socket, remove the switch from the expansion valve.
INSTALLATION
WARNING: THE REFRIGERATION SYSTEM MUST BE COMPLETELY RECOVERED BEFORE PROCEEDING WITH THIS OPERATION. REFER TO REFRIGERANT RECOVERY.
NOTE: Verify the O-ring condition on the replacement switch.
1. Using a sender unit socket, install the low pressure cutout switch into the expansion valve.
2. Connect the wire harness connector to the switch.
3. Evacuate the A/C refrigerant system.
4. Recharge the A/C system.