FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Power Seat - New Motor Replacement Procedures

NUMBER: 08-040-00

GROUP: Electrical

DATE: Dec. 8, 2000

SUBJECT:
Motor Replacement - Power Seat Slide Adjuster

OVERVIEW:
This bulletin describes new procedures for replacement of the seat motor which is now serviced separately.

MODELS:
1995 - 2000 FJ Avenger/Sebring/Talon

DISCUSSION:
New components and a repair procedure have been developed to replace failed seat slide motors. The process for replacing a motor as compared to a seat assembly will reduce repair time and component cost along with increasing customer satisfaction in the event this repair is required.

DIAGNOSIS/REPAIR PROCEDURES:
Determine if the motor has failed as follows:

1. Check fuses applicable to the circuit.

2. Check for power (12 v) to and from the switch while operating the switch.

3. Check for power (12 v) at the motor while operating the switch.

If power is available at the motor and the slide motor will not function,
perform the Repair Procedure.





PARTS REQUIRED:





EQUIPMENT REQUIRED:

REPAIR PROCEDURE:





1. Remove the seat from the vehicle and place it on a work bench as shown (Fig. 1).

NOTE:
THE SEAT DOES NOT REQUIRE DE-TRIMMING.

2. Snip the wire tie from the motor. Note the position for later reinstallation.





3. Using pliers, squeeze the harness retaining clip to remove it form the harness tray (Fig. 2).

4. Disconnect the motor connector from the harness.





5. Using a 3 mm allen wrench, loosen the screws from the left and right reducers.





6. Using the T-20 torx and extension, remove the 4 motor bracket screws.





7. Remove the motor assembly and place it on the bench as shown (Fig. 5).





8. Remove the flexi-shafts from the motor and discard the old motor (Fig. 6).

9. Using the new motor from kit p/n MR311167, reattach the flexi-shafts.





10. Reattach the left and right reducers to the seat as shown (Fig 7).

11. Install 4 new motor attaching screws.

12. Attach the jumper from kit p/n MR311167 to the motor and harness.

13. Insert the retainer clip back into the motor tray and secure the harness to the motor with the tie strap. Cut the excess tie strap off.

14. Reinstall the seat into the vehicle.

15. Check seat for proper operation.

POLICY:
Reimbursable within the provisions of the warranty.





TIME ALLOWANCE:





FAILURE CODE: Could be one or more