P0732
Test 1 Through 3:
Test 4 Through 5:
Symptom:
P0732-GEAR RATIO ERROR IN 2ND
When Monitored and Set Condition:
P0732-GEAR RATIO ERROR IN 2ND
When Monitored:
The transmission gear/speed ratio is monitored continuously while the transmission is in gear.
Set Condition:
Code P0732 is set if the ratio of the input RPM to the output RPM does not match the given gear ratio.
POSSIBLE CAUSES
CHECKING SYMPTOMS AND POSSIBLE CAUSES
LOW BATTERY VOLTAGE
INTERMITTENT CODE P0732
Test 1 Through 2:
Test 3 Through 7:
Test 8 Through 9:
symptom:
ADDITIONAL GEAR RATIO ERROR IN 2ND (P0732)
POSSIBLE CAUSES
INTERMITTENT 2ND GEAR SLIPPAGE
UD AND 2-4 CVI OUT OF SPEC
UD AND 2-4 PRESSURE < 105 PSI
UD PRESSURE < 5 PSI IN 4TH GEAR
TRANSAXLE DEFECT (2-4 SEALS)
2-4 ACCUM SEALS DAMAGED
UD ACCUMULATOR SEALS DAMAGED
TRANSAXLE DEFECT(UD SEALS)
TRANSAXLE SEALS ARE DEFECTIVE
UD PRESSURE > 5 PSI IN 4TH GEAR
TRANS HAS PLASTIC 2-4 ACCUM/SEAL