Driver Squib Circuit Open (Stored)
Test 1:
SYMPTOM
DRIVER SQUIB CIRCUIT OPEN (STORED)
TEST NOTE
This symptom is diagnosed using the test AECM & CLUSTER CCD MESSAGE MISMATCH (STORED).
WHEN MONITORED
Continuously with ignition ON.
SET CONDITION
The ACM has detected an open circuit or high resistance in the Driver Squib Circuits.
POSSIBLE CAUSES
- Stored code has become active
- Stored code has not been reproduced