Passenger Door Ajar Circuit Shorted
Test 1 - 4:
SYMPTOM
SHORTED PASSENGER DOOR AJAR CIRCUIT
POSSIBLE CAUSES
- Passenger door ajar switch DEF shorted (JX)
- Passenger ajar sense CKT SCMB shorted (JX)
- Passenger ajar switch CKT DEF <5 ohms to GND (JX)
- Seat belt control module switch def open (JX)
- Body control module defective closed (JX)