Low Pressure Sensor / Switch: Service and Repair
WARNING: THE REFRIGERATION SYSTEM MUST BE COMPLETELY RECOVERED BEFORE PROCEEDING WITH THIS OPERATION. REFER TO REFRIGERANT RECOVERY.REMOVAL
1. Disconnect the wire connector at the cut off switch.
Expansion Valve And Low Pressure Cut-Off Switch:
2. Using a sender unit removal socket, remove the switch from the expansion valve.
INSTALLATION
NOTE: Verify the O-ring condition on the replacement switch.