Compressor HVAC: Testing and Inspection
The compressor used on this vehicle is a Nippondenso 10PA17 R134a. This compressor uses an aluminum swash plate, teflon coated pistons and aluminum cylinder walls. One-way check valves are used to regulate refrigerant flow through the compressor.CAUTION: A 10PA17 R-12 compressor looks identical to a 10PA17 R134a and will bolt up to this vehicle. It is extremely important that a R-134a compressor is identified prior to using compressor in question. Check tag located on compressor for model number.
Excessive noise that occurs when the air-conditioning is being used may be caused by:
- Loose Bolts
- Mounting Brackets
- Loose Compressor Clutch
- Excessive High Refrigerant Operating Pressure
Verify the following before compressor repair is performed:
1. Compressor drive belt condition
2. Proper refrigerant charge
3. Thermal expansion valve (TXV) operating correctly
4. Head pressure is normal