Fuel Injector: Testing and Inspection
Measurement of Resistance between Terminals
1. Remove the injector connector.
2. Measure the resistance between terminals.
Standard value: 13 - 16 ohm [at 20°C (68°F)]
If not within specifications, replace the injector.
3. Install the injector connector