FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

P0134

Tests 163 - 167:




Tests 168 - 170:




SYMPTOM
P-0134 O2 SENSOR 1/1 STAYS AT CENTER

WHEN MONITORED
With the engine running for more than 2 minutes and engine temperature greater than 170 degrees.

SET CONDITION
The upstream oxygen sensor signal voltage is between 0.35 volt and 0.55 volt for 1.5 minutes.

POSSIBLE CAUSES
- O2 sensor 1/1 ground circuit open
- O2 sensor 1/1 signal circuit open
- O2 sensor 1/1 wiring harness intermittent defect
- O2 sensor 1/1 wiring harness observable defect
- O2 sensor 1/1 connector observable defect
- O2 sensor defective
- PCM defective