Driver Squib Terminal Shorted to Ground (Active)
SYMPTOMDRIVER SQUIB TERMINAL SHORTED TO GROUND (ACTIVE)
WHEN MONITORED
Continuously with the ignition on.
SET CONDITION
With voltage on, the driver airbag line 1 or line 2 circuit(s) is other than expected.
POSSIBLE CAUSES
- Driver airbag line 1 or line 2 short to ground
- Clockspring short to ground
- Driver side airbag module internal short to ground
- ACM DEF driver airbag terminal short to ground