60 Hex
Scan Tool 96 (MIL 66):
Trouble Code Number
- Scan tool 96
- General scan tool P1698
- MIL 66
Fault Message
No CCD Messages From Electronic Automatic Transaxle Electronic Control Module (EATX-ECM)
- The EATX-ECM outputs no CCD messages.
Probable Cause
- Communication line between PCM and EATX-ECM failed
- EATX-ECM failed
- PCM failed