Shift Linkage: Description and Operation
CIRCUIT OPERATIONThe auto stick is used to allow the operator to control the shifting of the transmission. This system uses hall effect switched located at the base of the shifter.
There are two hall effect switched used. One is for Upshift. Circuit T5 connects from the Upshift switch to the Transmission Control Module (TCM). Circuit T44 connects from the Downshift switch to the TCM.
Power for the switched is supplied on circuit F11. This circuit is HOT in the OFF/RUN/START position. This circuit is protected by a 10 amp fuse located in cavity 10 of the junction block.
Ground for the switch is supplied on circuit Z1.